4 Channel Input/Output Interface

The AST’s 4 Channel Input/Output Interface is a auxiliary powered input / output device providing 2 local zones of conventional detectors, 2 monitored inputs, 2 local monitored alarm outputs and two volt free changeover contacts. The contacts may be used to connect to ancillary equipment.

2 Channel Input/Output Interface

The AST 2 Channel Input/Output Interface is a loop powered input / output device providing 2 monitored inputs and two volt free changeover contacts. The contacts may be used to connect to ancillary equipment.

2 Channel Loop Powered Zone Alarm Interface

The AST’s 2 way loop zone alarm interface is a loop powered input / output device providing 2 local zones of conventional detectors and 2 local monitored alarm outputs.

6000 2 LPZA

6000 Monitored Input/Output Fire Alarm Interface

The AST 2 Channel Ancillary Powered Zone Alarm Interface is an auxiliary powered input / output device providing 2 local zones of conventional detectors and 2 local monitored alarm outputs.

6000 Monitored Input/Output Fire Alarm Interface

The 6000 series MICCO is a loop powered fault monitored input and a volt free clean contact output interface. An on-board isolator is provided which protects against loop short circuits on either the incoming or outgoing loop connections.

Under normal circumstances the input is terminated with an End of Line resistor. If the correct value of resistance is placed across the monitored input, the MICCO will activate the associated 6000 control panel within 3 seconds. The input is fully monitored for open and short circuit wiring faults.

Single Channel Loop Powered Zone Alarm Interface

The 6000 Single channel loop powered zone alarm interface which interfaces the 6000 series intelligent addressable loop to a zone of conventional devices and a conventional sounder circuit.

Most suitable to be used on small conventional fire detectors, it can be fully integrated with AST’s range of Intelligent addressable systems. The interface is powered using an external EN54 Part 4 power supply and can support up to 20 AST conventional (3000PLUS) detectors.

Single Channel Ancillary Powered Zone Alarm Interface

The AST 6000 Single Channel Ancillary Powered Zone Alarm Interface enables the 6000 series intelligent addressable loop to interface to a zone of conventional devices and a conventional sounder circuit.

This interface is suited for small conventional fire detection to be fully integrated with AST’s range of advanced technology addressable systems. It is powered using an external EN54 Part 4 power supply and can support up to 20 of AST’s conventional (3000PLUS) detectors.

Fire Beam Interface

The AST Fire Beam Interface is an unit which enables AST’s 6000 series of intelligent addressable loop systems to interface to conventional devices.

It is suited to interface ancillary conventional devices such as beam detectors and linear heat detection with our advanced addressable fire alarm systems. The fire beam interface is loop powered and does not require an external power supply.

Smoke and Vent Control

The Damper Control Module is an innovative fire alarm interface that is built following standards and guidelines under EN54 Part 17 and 18. It controls the heating ventilation and air conditioner systems directly from a fire alarm system in a building.